TM 5-4310-452-14
4-62. SHUTDOWN RELAY REPLACEMENT.
This Task Covers:
a. Removal b. Installation
Initial Setup:
Equipment Conditions: Materials/Parts:
Two self -locking nuts
Engine off. Two self-locking nuts
Left door assembly open.
Battery cables disconnected (see paragraph Tools/Test Equipment:
4-57). General mechanic's tool kit
a. REMOVAL
1. Disconnect 5 electrical leads (5) from shutdown
relay (1).
2. Remove 2 self-locking screws (3), nuts (2), and
shutdown relay (1) from control panel (4). Discard
self-locking screws and nuts.
b. INSTALLATION
1. Position shutdown relay (1) in place on control panel
(4) and install 2 new self-locking screws (3) and nuts
(2).
2. Connect 5 electrical leads (5) to shutdown relay (1).
FOLLOW-ON TASKS:
Connect battery cables (see paragraph 4-57).
Close left door assembly.
TA505498