TM 5-4310-452-14
Table 4-1. Organizational Preventive Maintenance Checks and Services (PMCS) (Con't).
Q - Quarterly S - Semiannual H - Hours
INTERVAL
ITEM ITEM TO BE INSPECTED PROCEDURES
NO. Q S H
10 AIR SILENCER
• Remove, clean, and inspect air silencer (see paragraph 4-94).
11 DRAWBAR
• Check drawbar mounting bolts for proper torque of
180-200 lb. -ft (244-271 N*m).
4-7/(4-8 Blank)