TM 5-4310-452-14
Table 2-1. Operator Preventive Maintenance Checks and Services (PMCS) (Con't).
B-Before D-During A-After W-Weekly
Interval ITEM TO BE INSPECTED Equipment is
Item PROCEDURE: Check for and have repaired Not Ready
No. B D A W filled or adjusted as needed Available If:
12 INSTRUMENTS AND GAGES
Check for proper indication and operation. Any gage inoperative or not
within limits.
Fuel pressure: 4-6 psi (28-41 kPa)
Oil pressure: 60-80 psi (414-552 kPa)
Discharge pressure: 80-120 psi (552-827 kPa)
Ammeter: Should indicate positive (+)
charge
Tachometer: 1400 rpm idle to 2500 rpm
max
Compressor
temperature: 150°F-230°F (66°C-110°C)
after 10 minutes of operation
13 SAFETY RELIEF VALVE
Pull up on ring (3) of safety relief valve (4). Safety
relief valve should open and allow air pressure to es-
cape. If valve will not open, notify your supervisor.
14 SERVICE AIR MANIFOLD
Open and drain moisture from service air manifold
drain (5).
TA505400
2-12